The new user library package V4.6.0 is now available and it will be possible to download it from our homepage.
Simplified Installation The former division into different packages has been cancelled. Now, there is only one package with the following user libraries
Basic blocks:
| GENERAL |
|
Version 4.1.4 |
|
Main group |
| CONVERT |
|
Version 4.2.0 |
|
Conversions |
| COM_CAN |
|
Version 4.2.1 |
|
Communication via CAN interface | Communication application blocks:
CAN:
| CANOPEN |
|
Version 4.0.2 |
|
CANopen protocol |
| COPMASTER_1 |
|
Version 3.1.0 |
|
CANopen master |
| COP_SLAVE |
|
Version 2.0.3 |
|
CANopen slave |
| COP_MODBUS |
|
Version 1.0.2 |
|
Modbus via CANopen |
| J1939 |
|
Version 4.5.1 |
|
CAN J1939 |
| J1939_CAT |
|
Version 1.0.0 |
|
CAN J1939 CATERPILLAR |
| J1939_DEUTZ |
|
Version 1.0.0 |
|
CAN J1939 DEUTZ |
| J1939_IVECO |
|
Version 1.0.0 |
|
CAN J1939 IVECO |
| J1939_MAN |
|
Version 1.0.0 |
|
CAN J1939 MAN
|
| J1939_SCANIA |
|
Version 1.0.0 |
|
CAN J1939 SCANIA |
| J1939_SIEMENS |
|
Version 1.0.0 |
|
CAN J1939 SIEMENS |
Serial:
| COM_SIO |
|
Version 3.0.1 |
|
Serial data transfer master slave |
| MODBUS |
|
Version 4.1.0 |
|
Modbus master and slave | Ethernet:
| MODBUS_IP |
|
Version 1.0.4 |
|
Modbus IP master and slave | TBC train bus:
| TBC |
|
Version 1.2.0 |
|
Basic train bus communication |
| SELE_TCN |
|
Version 2.2.0 |
|
Communication of inter-train data to TCN |
| SeleUIC |
|
Version 2.3.0 |
|
Communication of inter-train data to UIC | MVB:
| MVB_COM |
|
Version 1.0.4 |
|
MVB communication |
Control and monitoring application blocks:
| CTR_MCR |
|
Version 4.1.6 |
|
Control engineering blocks |
Operating terminal application blocks:
| HMI_SIO |
|
Version 3.0.0 |
|
HMI to serial interface (VT100) |
| HMI_COP |
|
Version 3.0.0 |
|
HMI to CANopen |
A new key is required for installation.
The division into individual *.sul files is retained.
Expansions and improvements to the libraries
COM_CAN:
Improved performance of the CAN_DISP_SET_CAN_FILTER function block.
COPMASTER_1:
Parameters can be set for resetting the input and status data of the DDC732 on communication interruption. New modules UIOC714, UIT714, UOT714 and UIOT714 added. Signaling the statuses of the CAN input and output queue. New block (COPM_UIOC71x_CNF) for configuring the UIOC71x.
COP_MODBUS:
Adaptations for use with COM_CAN V4.2.1.
J1939:
Various corrections and expansions of the DM1, DM2 and DM5 blocks. Division of the J1939 user library into different, manufacturer-specific user libraries (J1939_CAT, _DEUTZ, _IVECO, _MAN, _SCANIA, _SIEMENS). Send interval of all transmit blocks corrected. Function blocks (J1939_PGN_SEND and J1939_PGN_RECV) for sending and receiving any messages.
MODBUS:
New function block (MODBUS_SLAVE_EXT) for data exchange via an integer array with 65535 elements.
MODBUS_IP:
Improved processing speed of the function block (MODBUS_SERVER) when operating with several clients
TBC:
Parameters can be set for checking the train composition (slaves present at both ends). Improved train setup CAN queue overruns are monitored and prevented.
SELE_TCN:
New TBC_REDUNDANT function block permits redundant train bus communication with two TBCs. Data is now only sent to the TBC when it is in operational status. New parameter (xSendDataFirstStrongMaster) for defining the behavior when changing the strong master.
SELEUIC:
Expanded UIC_MAIN function block permits redundant train bus communication with two TBCs. Data is now only sent to the TBC when it is in operational status. New parameter (xSendDataFirstStrongMaster) for defining the behavior when changing the strong master. New parameter (xChkTrainComp) for setting the parameters for checking the train composition.
MVB_COM:
New user library for MVB communication with CPU733-TG.
|