Software tools for Symphony® release 5.3
All the software tools listed below are now available and can be downloaded from our website.
New CAP1131 V5.3.1516
The following new functions are integrated:
Expansions
- The new "List import" function is available for headers and POUs
- Import and export of configured PLC-Config nodes
- Configurable detection of "Back Jumps" and "Unused Variables"
- Improved integration of "Visual Source Safe" and "Subversion", and better support for ULibs in separate projects.
- „Content Assist“: helps you write code faster and accurately
- Automatic MOS update during the download of a project (external call on WDLD no longer needed).
- Improvement in global variable declaration.
- Improved task pool editor
- Automatic naming of FBD instances in the FBD editor
- Sorting variables in the header by clicking on Class, Identifier, Type, Initial or Comment
- Alphabetical sorting of objects in the "Entry Data Monitoring" and "Monitor Header"
- "Group" view for POU implementation and improved organization
- Expanded menu bar with new icons
- Doubling the capacity of ST and C-editor to 64K
TOP 1131 V3.2.1
The following new functions are integrated:
- Support for CPU 831-TG
- Improved support for the data logger
WDLD1131 V2.9.0
The following new functions are integrated:
Expansions and improvements
New MOS V507.25B4 run-time system
The following new functions are integrated:
- The MOS now contains the expansion modules AIT 731-TG/12B, AAT 731-TG/12B, CDT 731-TG
New MOS V600.AEE2 run-time system
The following new functions are integrated:
- The MOS now contains the CPU 831-TG
New SysCom PC SDK V3.0.0
The following new functions are integrated:
Expansions
New user library package V4.6.2
Simplified Installation The former division into different packages has been cancelled. Now, there is only one package with the following user libraries
Basic blocks:
| GENERAL |
|
Version 4.1.5 |
|
Main group |
| CONVERT |
|
Version 4.2.0 |
|
Conversions |
| COM_CAN |
|
Version 4.2.1 |
|
Communication via CAN interface | Communication application blocks:
CAN:
| CANOPEN |
|
Version 4.0.2 |
|
CANopen protocol |
| COPMASTER_1 |
|
Version 3.3.0 |
|
CANopen master |
| COP_SLAVE |
|
Version 2.0.3 |
|
CANopen slave |
| COP_MODBUS |
|
Version 1.0.2 |
|
Modbus via CANopen |
| J1939 |
|
Version 4.5.1 |
|
CAN J1939 |
| J1939_CAT |
|
Version 1.0.0 |
|
CAN J1939 CATERPILLAR |
| J1939_DEUTZ |
|
Version 1.0.0 |
|
CAN J1939 DEUTZ |
| J1939_IVECO |
|
Version 1.0.0 |
|
CAN J1939 IVECO |
| J1939_MAN |
|
Version 1.0.0 |
|
CAN J1939 MAN |
| J1939_SCANIA |
|
Version 1.0.0 |
|
CAN J1939 SCANIA |
| J1939_SIEMENS |
|
Version 1.0.0 |
|
CAN J1939 SIEMENS |
Serial:
| COM_SIO |
|
Version 3.0.1 |
|
Serial data transfer master slave |
| MODBUS |
|
Version 4.1.0 |
|
Modbus master and slave | Ethernet:
| MODBUS_IP |
|
Version 1.0.4 |
|
Modbus IP master and slave | TBC train bus:
| TBC |
|
Version 1.3.0 |
|
Basic train bus communication |
| SELE_TCN |
|
Version 2.2.0 |
|
Communication of inter-train data to TCN |
| SeleUIC |
|
Version 2.3.1 |
|
Communication of inter-train data to UIC | MVB:
| MVB_COM |
|
Version 1.0.4 |
|
MVB communication |
Control and monitoring application blocks:
| CTR_MCR |
|
Version 4.1.7 |
|
Control engineering blocks |
Operating terminal application blocks:
| HMI_SIO |
|
Version 3.0.0 |
|
HMI to serial interface (VT100) |
| HMI_COP |
|
Version 3.0.0 |
|
HMI to CANopen |
A new key is required for installation.
The division into individual *.sul files is retained.
Expansions and improvements to the libraries
GENERAL:
The automatic summer and winter time changeover has been revised. The new "RTC_SUMMER_CET" block is now used for the changeover. This block replaces the following existing functions: - RTC_GET_SUMMER - RTC_SUMMERTIME_A
COPMASTER_1:
In CAP1131_V5.3.1516, warnings were generated during compiling. Warnings have been rectified. In certain external nodes, the parameters were configured incorrectly if PDOs were set to inactive in the PLC config.
TBC:
The transparent train bus channel has been expanded so that data can also be exchanged between two train bus slave vehicles. This requires two new bits (gxATBCMaster and gxATBCSlave) which reconfigure a master vehicle as an ATBC slave and a slave vehicle as an ATBC master. The train bus communication is not affected by this definition.
CTR_MCR:
The CTR_ZONE_REAL and CTR_ZONE_DINT blocks function incorrectly when the value makes large jumps. Bug has been fixed.
|